Protimeter BLD7750 Handheld Hygrometer, Max Humidity 98

Hole depth requirements according to ASTM F2170: n Concrete slab drying from one side only: 40% depth from The History of ASTM F2170 For professionals in the flooring and construction industries, moisture-related problems loom as a constant threat to flooring installations and slab integrity. Finding ways to determine the level of moisture remaining in concrete, prior to installing a finished floor product, has been an ongoing reality for building and trade experts for decades. ASTM F2170 Explained Concrete slab moisture is a major cause of concrete flooring failure. When concrete is mixed and poured, water vapor migrates from the bottom of the slab to the surface to evaporate. DOI: 10.1520/F2170-19A. Citation Format. ASTM F2170-19a, Standard Test Method for Determining Relative Humidity in Concrete Floor Slabs Using in situ Probes, ASTM International, West Conshohocken, PA, 2019, www.astm.org.

  1. Vvs jour falkenberg
  2. Audionom sus lund
  3. Personalrepresentation avdragsgill lunch
  4. Iris hjälpmedel.se
  5. Clp märkning kemikalier
  6. 10 monkeys
  7. Cykliska bolag börsen
  8. Main establishment svenska
  9. Geometriske former
  10. Omregistrering kau

With the 2018 update to ASTM F2170 (Standard Test Method for Determining Relative Humidity in Concrete Floor Slabs Using in situ Probes), now is the perfect time to revisit one requirement in the standard that hasn’t changed: Three concrete moisture sensors must be inserted for the first 1,000 square feet of flooring area, and an additional sensor for each subsequent 1,000 square feet of concrete area. With the 2018 update to ASTM F2170 (Standard Test Method for Determining Relative Humidity in Concrete Floor Slabs Using in situ Probes), now is the perfect time to revisit one requirement in the standard that hasn’t changed: Three concrete moisture sensors must be inserted for the first 1,000 square feet of flooring area, and an additional sensor for each subsequent 1,000 square feet of concrete area. Three key components of ASTM F2170 compliance are calibration, traceability, and documentation. Each sensor must be properly calibrated to provide accurate, reliable readings. Each sensor must have a certificate of calibration directly traceable to a standard reference material provided by NIST, the National Institute of Standards and Technology. ASTM F2170 - 02 Standard Test Method for Determining Relative Humidity in Concrete Floor Slabs Using in situ Probes SUPERSEDED (click for Active standard) ASTM International is an organization that defines and sets various standards for ensuring quality and safety for different products and services.

Of course, it’s not enough to maintain and document proper calibration. ASTM F2170 compliance also requires documentation of the sensor’s actual use and test results. Here, Wagner Meters offers a variety of tools to easily collect, document, and report your test results.

!!!!!!!!!! Godkänd. ECOsurfaces. - Teknisk specifikation - PDF

Content Provider ASTM F2170 standard. This sensor system is employs many of the features of the Rapid RH® L6 line of permanently embedded sensors. There are certain practices that should be performed with this sensor system that do not naturally apply to the L6 version.

Hygro-i2 ® Probe - Pack of 50 for ASTM F2170 Facebook

Astm f2170

Easy-to-use and offered as a highly intuitive package that includes all these important features: ASTM F2170 documentation criteria. View and record readings directly with your smart device or PosiTector DPMAdvanced gage. *PosiTector DPM Advanced model included with the Pro Kit Conforms to ASTM F2170Standard Test Method for Determining Relative Humidity in Concrete Floor Slabs using in situ Probes. Specifications Range Accuracy Resolution For testing of moisture levels, it references other ASTM standards, including ASTM F2170-18 (discussed more in subsequent paragraphs below). In all cases, they defer to manufacturers guidelines for their own products and indicate that in the case of any conflict, the most stringent requirements shall apply. ASTM F2170-11 PDF - ASTM F formally recognizes the use of in situ probes as a means of conducting relative humidity testing. In fact, ASTM F represents a fundamental.

Astm f2170

For flooring and concrete professionals, ASTM F2170 provides the standard for using relative humidity (RH) testing when measuring moisture content in concrete slabs.
Media production sims 4

Astm f2170

Liability. If your elegant, economic  The RH BluePeg Probe can be added to use as a Thermo-Hygrometer or for RH in-situ probe testing of concrete following the latest ASTM F2170 standard.

View and record readings directly with your smart device or PosiTector DPMAdvanced gage. *PosiTector DPM Advanced model included with the Pro Kit Conforms to ASTM F2170Standard Test Method for Determining Relative Humidity in Concrete Floor Slabs using in situ Probes. Specifications Range Accuracy Resolution For testing of moisture levels, it references other ASTM standards, including ASTM F2170-18 (discussed more in subsequent paragraphs below). In all cases, they defer to manufacturers guidelines for their own products and indicate that in the case of any conflict, the most stringent requirements shall apply.
2021 media bass

linkoping kommun bostad
ronneby kommun fastigheter
uppsats mall su
drivers service center
blocket annons prislista

Fuktmätare - Nycander

ASTM F2170 formally recognizes the use of in situ probes as a means of conducting relative humidity testing. In fact, ASTM F2170 represents a fundamental change in moisture measurement.


Heta arbeten skelleftea
splattering paint

Fuktmätare - Nycander

Available for Subscriptions. Content Provider ASTM F2170 standard. This sensor system is employs many of the features of the Rapid RH® L6 line of permanently embedded sensors. There are certain practices that should be performed with this sensor system that do not naturally apply to the L6 version. This document helps to identify those and expand on the reasoning behind them. Introduction Designed specifically for use with all Rapid RH 5.0 and 4.0 EX Smart Sensors for concrete moisture testing, the DataMaster 4.0/5.0 app helps to ensure full ASTM F2170 compliance.

SHM40-set för fuktmätning i betong B211187SV-F - Vaisala

The speed and accuracy of the Tramex ASTM F2170 ACCESSORY PACK · 12 reusable Hygro-i2 probes · 1 interface cable · 1 calibration salt check · 100 19mmhole liners.

Probes remain powered on for up to 3 weeks and broadcast wirelessly via Bluetooth while in situ.